SF6 Gas Leak Detection And Analysis

  • GDSF-311WPD 3-In-1 SF6 Gas Analyzer

    GDSF-311WPD 3-In-1 SF6 Gas Analyzer

    GDSF-311WPD (GDSF-411WPD) is an ideal instrument when it is necessary to test water content, purity and decomposition products of SF6 gas. The core component of dew point test is DRYCAP®  series sensors produced by Finland Vaisala company. 

  • GLF-314 SF6 Gas Infrared Imaging Leak Detector

    GLF-314 SF6 Gas Infrared Imaging Leak Detector

    The SF6 infrared imaging leak detector is a non-contact gas imaging leak detection device that can detect possible gas leaks at several meters or tens of meters. It can quickly scan a large detection area and accurately find leaks in real time.

     The gas detection thermal imager can detect the leakage or unorganized emission of organic volatiles, and still has good performance even for very small gas leakage.

     The use of gas leakage detection is an efficient and reliable solution, which can detect the leakage of natural gas products in various links such as transportation, storage and production, so as to maximize safety and save costs.

  • GDP-713PM SF6 Gas Dew Point Tester (Chilled Mirror Method)

    GDP-713PM SF6 Gas Dew Point Tester (Chilled Mirror Method)

    GDP-713PM Portable Chilled Mirror SF6 Gas Dew Point Tester is specially designed for SF6 gas micro moisture detection. The perfect combination of high-quality dew point sensor and intelligent electronic control technology makes it successfully applied to accurate measurement of dew point under various environmental conditions.

    The dew point measurement is based on the principle of chilled mirror. The water vapor in the measured gas is condensed into water or frost on the mirror surface through semiconductor cold reactor cooling. When the two-phase equilibrium of water in the gas is reached, the temperature of the mirror surface is measured at this time, that is the dew point or frost point.

    Compared with other forms of dew point meter, the chilled mirror dew point meter measures the dew point temperature more accurately, and at the same time has the characteristics of good measurement repeatability, stable and reliable measurement results, and easy operation.

    GDP-713PM portable cooling method SF6 gas dew point meter is a standard instrument for humidity measurement in the fields of electric power, gas, meteorology, electronics, petroleum, chemical industry, measurement, etc. It is an ideal choice for establishing a humidity standard device.

  • GDP-8000CM SF6 Gas Dew Point Tester (Chilled Mirror Method)

    GDP-8000CM SF6 Gas Dew Point Tester (Chilled Mirror Method)

    GDP-8000CM Portable Chilled Mirror SF6 Gas Dew Point Tester is specially designed for SF6 gas micro moisture detection used in the whole temperature zone of the power industry, which is based on Stryn refrigeration and chilled mirror measuring principle.

  • GDQC-55A SF6 Gas Vacuuming and Filling Machine

    GDQC-55A SF6 Gas Vacuuming and Filling Machine

    GDQC-55A SF6 Gas Vacuuming and Filling Machine is mainly used for the installation, operation, and maintenance of 35kV~220kV ceramic column SF6 circuit breakers, transformers and other SF6 electrical appliances. It is a compact device, which is mounted on a strong metal frame, and walk freely even on gravel roads.

    It is suitable for SF6 electrical equipment, GIS manufacturer and research institute.

  • GD8000C SF6 Gas Leak Online Monitoring System

    GD8000C SF6 Gas Leak Online Monitoring System

    GD8000C quantitatively leak online monitoring system is mainly used in the 35KV SF6 switch room and 500KV, 220KV, 110KV GIS room in the substation to monitor the SF6 gas leakage in the SF6 combined electrical equipment room environment and the oxygen content in the air in real time.

  • GDFJ-311M SF6 Gas Decomposition Product Tester

    GDFJ-311M SF6 Gas Decomposition Product Tester

    GDFJ-311M SF6 Gas Decomposition Product Tester is a portable device designed to measure SF6 gas decomposition product.

  • GDP-311IR SF6 Gas Purity Tester (IR Method)

    GDP-311IR SF6 Gas Purity Tester (IR Method)

    GDP-311IR SF6 gas purity tester is a portable instrument for on site SF6 gas purity test developed by our company. 

  • GDSF-311WP SF6 Dew Point and Purity Tester

    GDSF-311WP SF6 Dew Point and Purity Tester

    GDSF-311WP is ideal instrument when it is necessary to test water content and purity of SF6 gas. The core component is DRYCAP series sensors produced by Finland Vaisala company. 

     

  • GDJD-3A SF6 Gas Density Relay Calibrator

    GDJD-3A SF6 Gas Density Relay Calibrator

    GDJD-3A SF6 gas Density Relay Calibrator is automatic calibrator, which uses embedded microprocessor to proceed performance calibration for all kinds of SF6 gas density relay. 

  • GDIR-1000L SF6 Gas Infrared Imaging Leak Detector

    GDIR-1000L SF6 Gas Infrared Imaging Leak Detector

    GDIR-1000L SF6 Gas Infrared Imaging Leak Detector  is a highly technical instrument which is independently developed by our company and has independent intellectual property rights.

  • GDP-8000CM SF6 Gas Dew Point Tester (Chilled Mirror Method)

    GDP-8000CM SF6 Gas Dew Point Tester (Chilled Mirror Method)

    GDP-8000CM Portable Chilled Mirror SF6 Gas Dew Point Tester is specially designed for SF6 gas micro moisture detection used in the whole temperature zone of the power industry, which is based on Stryn refrigeration and chilled mirror measuring principle.

Send your message to us:

Write your message here and send it to us